熱門關鍵詞:進口ELISA試劑盒,人ELISA試劑盒,大鼠elisa試劑盒價格,小鼠elisa試劑盒價格,豬elisa試劑盒,雞elisa試劑盒,兔elisa試劑盒,魚elsa試劑盒,其他種屬elisa試劑盒,豚鼠elisa試劑盒,倉鼠elisa試劑盒,裸鼠ELISA試劑盒,進口試劑,血清,動物血清,人血清,胎牛血清,氨基酸試劑,培養基,顯色培養基,大腸桿菌O157培養基,細菌總數培養基,金黃色葡萄球菌檢驗培養基,沙門氏菌/賀氏菌檢驗培養基, 弧菌檢驗培養基,其他培養基,酵母 霉菌 青霉 曲霉培養基, 李斯特氏菌檢驗培養基,抗體,二抗,一抗,生物試劑,酶生物試劑,蛋白質試劑,抗生素試劑,植物激素及核酸試劑,碳水化合物試劑,色素試劑,維生素試劑,表面活性劑,緩沖試劑,其他生化試劑,標準品對照品類,對照品,對照藥材,標準品,標準試劑,Spectrum試劑,美國藥典級試劑等

資料下載您現在的位置:首頁 > 資料下載 > 人腫瘤壞死因子α(TNF-α)說明書
人腫瘤壞死因子α(TNF-α)說明書
發布時間:2016/5/16   點擊次數:4312次

 

Human TNF-α

 

FOR RESEARCH USE ONLY

 

 

Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

 

Purpose

 

This kit allows for the determination of TNF-α concentrations in Human serum.

 

 

Principle of the assay

 

The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

Materials provided with the kit

 

1

washsolution

20ml×1bottle

7

Stop Solution

6ml×1 bottle

 

 

 

 

 

 

2

HRP-Conjugate reagent

6ml×1 bottle

8

Standard800ng/L

0.5ml×1 bottle

 

 

 

 

 

 

3

Microelisa stripplate

12well×8strips

9

Standard diluent

1.5ml×1bottle

 

 

 

 

 

 

4

Sample diluent

6ml×1 bottle

10

Instruction

1

 

 

 

 

 

 

5

Chromogen Solution A

6ml×1 bottle

11

Closure plate

2

membrane

 

 

 

 

 

6

Chromogen Solution B

6ml×1 bottle

12

Sealed bags

1

 

 

 

 

 

 

 

Specimen requirements

 

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

 

1

 

 

2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

 

Assay procedure

 

1. Dilute and add sample:Dilute Original density Standard as follow table:

 

400ng/L

5

Standard

150µl Original density Standard+150µl Standard diluent

 

 

 

 

 

200ng/L

4

Standard

150µl 5 Standard+150µl Standard diluent

 

 

 

 

 

100ng/L

3

Standard

150µl 4 Standard+150µl Standard diluent

 

 

 

 

 

50ng/L

2

Standard

150µl 3 Standard +150µl Standard diluent

 

 

 

 

 

25ng/L

1

Standard

150µl 2 Standard +150µl Standard diluent

 

 

 

 

 

 

2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

 

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

 

water and reserve.

 

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

 

6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

 

8.washingOperation with 5.

 

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

 

10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

 

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

 

within 15min.

 

Steps description

 

 

 

 

2

 

 

Standard, Sample diluent

 

 

 

 

 

 

 

Add Standard, Sample diluent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

 

 

 

 

 

 

 

Add Stopp Solution

 

 

 

 

 

 

 

Read absorbance at 450nm within 15 min

 

 

 

 

 

 

 

calculate

 

Calculate

 

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

 

3

 

 

the result is the sample actual density.

 

Important notes

 

  • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

 

  • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

 

  • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

 

  • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

 

  • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

 

  • The substrate evade the light preservation.

 

  • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

 

  • All samples, washing buffer and each kind of reject should according to infective material process.

 

  • Do not mix reagents with those from other lots.

 

 

 

Storage and validity

 

1Storage 2-8.

 

2validity six months

 

 

 

 

 

 

 

 

 

 

 

4

 

Human TNF-α

 

FOR RESEARCH USE ONLY

 

 

Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

 

Purpose

 

This kit allows for the determination of TNF-α concentrations in Human serum.

 

 

Principle of the assay

 

The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

Materials provided with the kit

 

1

washsolution

20ml×1bottle

7

Stop Solution

6ml×1 bottle

 

 

 

 

 

 

2

HRP-Conjugate reagent

6ml×1 bottle

8

Standard800ng/L

0.5ml×1 bottle

 

 

 

 

 

 

3

Microelisa stripplate

12well×8strips

9

Standard diluent

1.5ml×1bottle

 

 

 

 

 

 

4

Sample diluent

6ml×1 bottle

10

Instruction

1

 

 

 

 

 

 

5

Chromogen Solution A

6ml×1 bottle

11

Closure plate

2

membrane

 

 

 

 

 

6

Chromogen Solution B

6ml×1 bottle

12

Sealed bags

1

 

 

 

 

 

 

 

Specimen requirements

 

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

 

1

 

 

2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

 

Assay procedure

 

1. Dilute and add sample:Dilute Original density Standard as follow table:

 

400ng/L

5

Standard

150µl Original density Standard+150µl Standard diluent

 

 

 

 

 

200ng/L

4

Standard

150µl 5 Standard+150µl Standard diluent

 

 

 

 

 

100ng/L

3

Standard

150µl 4 Standard+150µl Standard diluent

 

 

 

 

 

50ng/L

2

Standard

150µl 3 Standard +150µl Standard diluent

 

 

 

 

 

25ng/L

1

Standard

150µl 2 Standard +150µl Standard diluent

 

 

 

 

 

 

2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

 

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

 

water and reserve.

 

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

 

6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

 

8.washingOperation with 5.

 

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

 

10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

 

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

 

within 15min.

 

Steps description

 

 

 

 

2

 

 

Standard, Sample diluent

 

 

 

 

 

 

 

Add Standard, Sample diluent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

 

 

 

 

 

 

 

Add Stopp Solution

 

 

 

 

 

 

 

Read absorbance at 450nm within 15 min

 

 

 

 

 

 

 

calculate

 

Calculate

 

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

 

3

 

 

the result is the sample actual density.

 

Important notes

 

  • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

 

  • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

 

  • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

 

  • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

 

  • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

 

  • The substrate evade the light preservation.

 

  • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

 

  • All samples, washing buffer and each kind of reject should according to infective material process.

 

  • Do not mix reagents with those from other lots.

 

 

 

Storage and validity

 

1Storage 2-8.

 

2validity six months

 

 

 

 

 

 

Human TNF-α

 

FOR RESEARCH USE ONLY

 

 

Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

 

Purpose

 

This kit allows for the determination of TNF-α concentrations in Human serum.

 

 

Principle of the assay

 

The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

Materials provided with the kit

 

1

washsolution

20ml×1bottle

7

Stop Solution

6ml×1 bottle

 

 

 

 

 

 

2

HRP-Conjugate reagent

6ml×1 bottle

8

Standard800ng/L

0.5ml×1 bottle

 

 

 

 

 

 

3

Microelisa stripplate

12well×8strips

9

Standard diluent

1.5ml×1bottle

 

 

 

 

 

 

4

Sample diluent

6ml×1 bottle

10

Instruction

1

 

 

 

 

 

 

5

Chromogen Solution A

6ml×1 bottle

11

Closure plate

2

membrane

 

 

 

 

 

6

Chromogen Solution B

6ml×1 bottle

12

Sealed bags

1

 

 

 

 

 

 

 

Specimen requirements

 

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

 

1

 

 

2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

 

Assay procedure

 

1. Dilute and add sample:Dilute Original density Standard as follow table:

 

400ng/L

5

Standard

150µl Original density Standard+150µl Standard diluent

 

 

 

 

 

200ng/L

4

Standard

150µl 5 Standard+150µl Standard diluent

 

 

 

 

 

100ng/L

3

Standard

150µl 4 Standard+150µl Standard diluent

 

 

 

 

 

50ng/L

2

Standard

150µl 3 Standard +150µl Standard diluent

 

 

 

 

 

25ng/L

1

Standard

150µl 2 Standard +150µl Standard diluent

 

 

 

 

 

 

2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

 

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

 

water and reserve.

 

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

 

6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

 

8.washingOperation with 5.

 

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

 

10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

 

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

 

within 15min.

 

Steps description

 

 

 

 

2

 

 

Standard, Sample diluent

 

 

 

 

 

 

 

Add Standard, Sample diluent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

 

 

 

 

 

 

 

Add Stopp Solution

 

 

 

 

 

 

 

Read absorbance at 450nm within 15 min

 

 

 

 

 

 

 

calculate

 

Calculate

 

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

 

3

 

 

the result is the sample actual density.

 

Important notes

 

  • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

 

  • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

 

  • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

 

  • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

 

  • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

 

  • The substrate evade the light preservation.

 

  • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

 

  • All samples, washing buffer and each kind of reject should according to infective material process.

 

  • Do not mix reagents with those from other lots.

 

 

 

Storage and validity

 

1Storage 2-8.

 

2validity six months

 

 

 

 

 

 

Human TNF-α

 

FOR RESEARCH USE ONLY

 

 

Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

 

Purpose

 

This kit allows for the determination of TNF-α concentrations in Human serum.

 

 

Principle of the assay

 

The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

Materials provided with the kit

 

1

washsolution

20ml×1bottle

7

Stop Solution

6ml×1 bottle

 

 

 

 

 

 

2

HRP-Conjugate reagent

6ml×1 bottle

8

Standard800ng/L

0.5ml×1 bottle

 

 

 

 

 

 

3

Microelisa stripplate

12well×8strips

9

Standard diluent

1.5ml×1bottle

 

 

 

 

 

 

4

Sample diluent

6ml×1 bottle

10

Instruction

1

 

 

 

 

 

 

5

Chromogen Solution A

6ml×1 bottle

11

Closure plate

2

membrane

 

 

 

 

 

6

Chromogen Solution B

6ml×1 bottle

12

Sealed bags

1

 

 

 

 

 

 

 

Specimen requirements

 

  • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

 

1

 

 

2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

 

Assay procedure

 

1. Dilute and add sample:Dilute Original density Standard as follow table:

 

400ng/L

5

Standard

150µl Original density Standard+150µl Standard diluent

 

 

 

 

 

200ng/L

4

Standard

150µl 5 Standard+150µl Standard diluent

 

 

 

 

 

100ng/L

3

Standard

150µl 4 Standard+150µl Standard diluent

 

 

 

 

 

50ng/L

2

Standard

150µl 3 Standard +150µl Standard diluent

 

 

 

 

 

25ng/L

1

Standard

150µl 2 Standard +150µl Standard diluent

 

 

 

 

 

 

2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

 

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

 

water and reserve.

 

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

 

6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

 

8.washingOperation with 5.

 

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

 

10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

 

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

 

within 15min.

 

Steps description

 

 

 

 

2

 

 

Standard, Sample diluent

 

 

 

 

 

 

 

Add Standard, Sample diluent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

 

 

 

 

 

 

 

Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

 

 

 

 

 

 

 

Add Stopp Solution

 

 

 

 

 

 

 

Read absorbance at 450nm within 15 min

 

 

 

 

 

 

 

calculate

 

Calculate

 

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

 

3

 

 

the result is the sample actual density.

 

Important notes

 

  • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

 

  • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

 

  • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

 

  • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

 

  • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

 

  • The substrate evade the light preservation.

 

  • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

 

  • All samples, washing buffer and each kind of reject should according to infective material process.

 

  • Do not mix reagents with those from other lots.

 

 

 

Storage and validity

 

1Storage 2-8.

 

2validity six

文件下載    圖片下載    
主站蜘蛛池模板: 大陆国语对白国产av片| 50路60路老熟妇啪啪| yy111111少妇影院| 天天弄天天模| 国产美女裸体无遮挡免费视频| 亚洲无av在线中文字幕| 久久亚洲精品国产亚洲老地址| 国产精品成人av片免费看| 人妻丰满av无码中文字幕| 色欲av无码一区二区三区| 少妇性俱乐部纵欲狂欢电影| 亚洲色婷婷一区二区三区| 日韩av无码久久精品免费| 亚洲av成人无遮挡网站在线观看| 女的被弄到高潮娇喘喷水视频| 国产精品无码免费播放| 中国少妇xxxx做受| 日韩精品少妇无码受不了| 欧洲乱码伦视频免费| 成全动漫在线观看免费高清| 推油少妇久久99久久99久久| 真实国产老熟女粗口对白| 九九精品成人免费国产片| 国产精品美女久久久网av| 无码丰满熟妇| 亚洲女同一区二区| 欲妇荡岳丰满少妇岳| 日韩av片无码一区二区不卡电影| 亚洲av永久无码区成人网站| 欧美性xxxxx极品娇小| 双腿张开被9个男人调教| 日韩国产成人精品视频| 在线观看亚洲av日韩av| 强行糟蹋人妻hd中文| 国产精品偷伦视频免费观看了| 国内精品九九久久久精品| 12孩岁女a处破娇小| 免费人成视频网站在线下载| 色久综合网精品一区二区| 久久久无码人妻精品无码| 久久国产精品免费一区下载|